HIGH VOLTAGE INSULATION TESTER IR3455
Maximum 5kV Test Voltage – Up to 10 Teraohm of Insulated Resistance Testing
Key Features
- Measure insulation of high-voltage equipment (such as transformers, cables, and motors)
- Wide testing voltage range, up to 5.00 kV from 250 V DC
- Wide measurement insulation range, up to 10 TΩ
- PI (Polarization Index) and DAR (Dielectric Absorption Ratio) automatically calculated / display
- Data memory function to reduce handwritten notes
- Bright LED luminous scale
- Extended operating temperature range of -10°C to 50°C
Flash Sale end in:

Delivery & Return
We want you to be happy with your purchase and we apologize if it is not. For whatever reason that you are not satisfied, we would be most happy to provide exchanges and returns for all items purchased from us if the following conditions are met.
Rules
All exchanges and returns would need to be raised within 10 days of the invoice date for Singaporeorders, and 20 days for overseas orders. For local deliveries, there is an option to exchange at any of our boutiques within Singaporeor through our online portal at www.company.com. All requests for returns however, would need to be strictly made online at www.company.com for both local and overseas deliveries.
Interpretation and Definitions
All exchanges and returns would need to be raised within 10 days of the invoice date for Singaporeorders, and 20 days for overseas orders. For local deliveries, there is an option to exchange at any of our boutiques within Singaporeor through our online portal at www.company.com. All requests for returns however, would need to be strictly made online at www.company.com for both local and overseas deliveries.
Wide Range of Voltage Generated for Measurement and Testing
Insulation resistance measurements:
Select a test voltage from 250 V, 500 V, 1.00 kV, 2.50 kV, and 5.00 kV. More finely graded settings are also possible. When measurement is completed, the unit shows the insulation resistance value, test voltage (setting and actual output), leakage current, DAR, PI, and elapsed time. Save measurement conditions and measurement results to internal memory, and view them on a computer.

Wide Range of Voltage Generated for Measurement and Testing
Step voltage test:
In this type of test, the voltage is gradually raised and the insulation resistance and leakage current change is measured. Two different step settings are available: 500 V -> 1 kV -> 1.5 kV -> 2 kV -> 2.5 kV and 1 kV -> 2 kV -> 3 kV -> 4 kV -> 5 kV.

User Support
Q & A
Related Products
Megger MIT420/2
Megger MTB7671/2
CT4641 High Insulation Tester
Megger MIT210-EN
Megger MIT200-EN
Megger MIT300-EN
Megger MIT230-EN
Megger MIT400/2
Product categories
- ANALOG MΩ HiTESTER 4
- Battery Testers 2
- Boom Barrier 2
- Calibration Instruments 3
- Clamp Multimeters 47
- DC Resistance Tester 0
- Digital Insulation Tester 4
- Digital Multimeter 39
- DMM 3
- Earth Tester 14
- EV Charger 4
- Infrared Thermometer 7
- Insulation Resistance Tester 15
- Loop and RCD Testing 4
- Magnetic Field 2
- Motor and Generator Testing 1
- Phase Detector 3
- Power Meter 6
- Power Quality Analyzers 6
- PV System Maintenance 5
- Uncategorized 0
- Voltage Detection 3








Reviews
There are no reviews yet